Align46
Field Project Manager - Data Center Liquid Cooling
Plano, Texas, United States
Apply through hirly
hirly scores this role against your resume, shows its reasoning, then writes a resume and cover letter for it and fills the application with you. Free to start — no card required.
hirly's read of this role
- Seniority
- Lead / management
- Stated salary
- $170,000 – $210,000 per year
- Country
- US
- Work mode
- On-site / unstated
- First seen by hirly
- 10 Sept 2026
Derived automatically from the posting. Sign up to see how the role scores against your own resume.
the posting
Join the Team!
Is technology your passion? Do you want to work with smart, forward-thinking individuals? Do you want to grow in a career you love?
At Align, our professionals are the key to our success. We don’t just hire talent, we invest in exceptional people who are forward-thinking, results-driven, and passionate about what they do. We’re a group of tech-savvy professionals who are motivated by making an impact. Our culture is one of unbounded opportunity that celebrates the passions, skills and ideas of our team—work hard, play hard, be smart!
We believe great communities lead to great companies. That’s why we offer a dynamic workplace where you feel inspired, engaged and innovative. We offer professionals opportunities to train in the leading technologies, make an impact within the industry and acquire valuable new skills whether on client sites or in one of our regional offices.
Position Overview
Align offers a wide variety of services centered around the data center white space. We are a fit-out specialist who manages the entire white space from conceptual design through execution across the country. Our services include designing layouts, overhead support systems (to support conveyance and electrical systems), power striping/redundancy planning for distribution from PDUs to cabinet receptacles, mechanical distribution from CDU to the rack or server, conduit pathways, and low voltage structured cable infrastructure.
We are seeking an experienced data center liquid cooling specialist to lead planning, estimating, and execution of advanced cooling infrastructure for hyperscale and AI data center white-space fit-outs. The successful candidate will combine hands-on technical expertise with strong project management skills, overseeing liquid cooling systems from design coordination and procurement through installation, testing, commissioning, and turnover. Ideal candidates have managed liquid cooling projects in hyperscale, AI, colocation, or other mission-critical environments and can effectively coordinate engineers, manufacturers, contractors, commissioning agents, operators, and construction teams.
Familiarity with broader data center MEP systems—including electrical distribution, structured cabling, and telecommunications—is a strong plus.
This is a full-time salaried role offering $170,000-$210,000 (commensurate with experience) full benefits, project bonuses, paid travel, and advanced training.
This position requires 50% travel to project sites nationwide, including AI build locations.
Key Responsibilities
Liquid Cooling Project Management
Lead data center liquid cooling projects from design coordination through installation, commissioning, and turnover.
Oversee direct-to-chip cooling, rear-door heat exchangers, technology cooling loops, CDUs, manifolds, piping, pumps, heat exchangers, filtration, and related infrastructure.
Integrate cooling systems with server racks, IT equipment, power distribution, containment, overhead infrastructure, and other white-space systems.
Manage scope, schedule, budget, procurement, subcontractors, vendors, quality, and documentation.
Serve as the technical liaison among Align, clients, engineers, contractors, manufacturers, commissioning agents, and other stakeholders.
Design & Technical Coordination
Review designs, drawings, submittals, specifications, equipment selections, and vendor proposals for functionality, constructability, maintainability, and compliance with project requirements.
Evaluate system capacity, flow, pressure, redundancy, controls, connections, and integration with IT equipment.
Coordinate with engineers, subcontractors, and field teams to identify design conflicts, installation constraints, and technical risks, then translate requirements into practical solutions.
Participate in design reviews, BIM coordination, and technical evaluations.
Construction Installation & Oversite
Direct mechanical subcontractors, specialty installers, construction managers, and field personnel during liquid cooling installation.
Verify compliance with approved documents, manufacturer requirements, and project quality standards.
Coordinate piping, equipment connections, rack interfaces, controls, leak detection, power, and supporting infrastructure.
Monitor quality, conduct field inspections and punch-list activities, and resolve deficiencies before commissioning or turnover.
Testing, Flushing & Commissioning
Coordinate filling, flushing, filtration, cleaning, pressure and leak testing, startup, functional testing, and integrated systems testing.
Review commissioning plans, procedures, performance tests, and documentation with contractors, manufacturers, commissioning agents, and operators.
Troubleshoot issues, coordinate corrective actions, and verify system readiness for high-density IT equipment before turnover.
Vendor & Subcontractor Coordination
Evaluate manufacturers, distributors, contractors, installers, and commissioning firms based on technical capability, experience, methodology, capacity, schedule, and commercial considerations.
Review proposals and technical information, support equipment and material procurement, and maintain strong industry relationships.
MEP Coordination
Coordinate liquid cooling with electrical distribution, busway, PDUs, rack power, structured cabling, telecommunications, controls, containment, overhead supports, and other white-space infrastructure.
Assess interdependencies among cooling capacity, electrical capacity, rack density, IT equipment, and supporting systems, and resolve cross-discipline conflicts.
Required Qualifications
The successful candidate is a practical, field-oriented subject matter expert who understands how liquid cooling systems work and how to coordinate, build, test, commission, and turn them over in mission-critical environments. The candidate must communicate effectively in design meetings, submittal reviews, field inspections, commissioning activities, and client discussions while driving technical issues toward practical resolution.
7+ years of project, construction, or technical management experience in data centers, mission-critical facilities, mechanical construction, or MEP construction.
Demonstrated experience managing liquid cooling projects in hyperscale, AI, or other high-density data centers.
Practical knowledge of direct-to-chip cooling, rear-door heat exchangers, CDUs, manifolds, piping, pumps, heat exchangers, filtration, controls, and related systems.
Experience overseeing installation, filling, flushing, filtration, pressure and leak testing, commissioning, and turnover.
Ability to interpret mechanical drawings, specifications, submittals, schematics, and construction documents and identify constructability issues.
Experience coordinating subcontractors, manufacturers, commissioning agents, and other trades.
Strong understanding of data center white-space construction and the relationship between cooling systems and IT infrastructure.
Strong project management skills across scope, schedule, budget, risk, quality, documentation, and subcontractor performance.
Willingness and ability to travel approximately 50% throughout the United States.
Preferred Qualifications
Experience with hyperscale, AI, NVIDIA GPU, or other high-density compute environments.
Experience with CDUs, liquid-to-liquid heat exchangers, facility water systems, secondary cooling loops, rack manifolds, quick disconnects, direct-to-chip distribution, rear-door heat exchangers, and technology cooling loops.
Experience with liquid cooling commissioning and integrated systems testing.
Experience with a data center general contractor, mechanical or MEP contractor, equipment manufacturer, or specialty liquid cooling contractor.
Knowledge of data center electrical distribution, structured cabling, and telecommunications infrastructur
Browse similar roles
Is this role actually a fit for you?
hirly answers with a score and its reasoning, then writes the resume and cover letter if you decide to go for it.
Score it against my resume