Amazon
Reliability & Maintenance Engineer
Delhi, Delhi, IND
Apply through hirly
Upload your resume and get a version tailored to this job, plus a cover letter, in about thirty seconds — before you create an account.
Apply with hirlyhirly's read of this role
- Seniority
- Mid level
- Country
- IN
- Work mode
- On-site / unstated
- First seen by hirly
- 27 Sept 2026
Derived automatically from the posting. Sign up to see how the role scores against your own resume.
the posting
- Key Responsibilities
- 1. Execute planned preventive maintenance (PPM) schedules for all refrigeration systems, including tropical rooms, chilled rooms, and frozen rooms.
- 2. Monitor and maintain optimal temperature parameters across all cold chain zones in strict accordance with defined Standard Operating Procedures (SOPs).
- 3. Conduct routine inspections of compressors, condensers, evaporators, expansion valves, and refrigerant piping systems.
- 4. Ensure refrigerant levels are maintained within specified limits and perform periodic leak detection tests.
- 5. Monitor and maintain defrost cycles, drain lines, and insulation integrity of all cold rooms.
- 6. Coordinate with Original Equipment Manufacturers (OEMs) and third-party service providers for specialized repairs and annual maintenance contracts.
- 7. Diagnose and resolve refrigeration system faults, including compressor failures, refrigerant leaks, thermostat malfunctions, and evaporator icing.
- 8. Respond to temperature excursion alarms and execute corrective actions within defined response timelines.
- 9. Troubleshoot electrical and control system faults in refrigeration panels, PLCs, and Building Management System (BMS) interfaces.
- 10. Perform root cause identification for recurring equipment failures and implements verified permanent fixes.
- 11. Maintain and monitor Diesel Generator (DG) sets, including fuel systems, coolant levels, battery health, and periodic load bank testing.
- 12. Execute preventive and predictive maintenance on Uninterruptible Power Supply (UPS) systems, including battery health checks, load testing, and firmware updates.
- 13. Monitor and maintain electrical panels — including Main Distribution Boards (MDB), Sub-Distribution Boards (SDB), Automatic Transfer Switches (ATS), and change-over panels.
- 14. Conduct periodic insulation resistance (IR) testing, earth resistance testing, and thermography surveys of all electrical systems.
- 15. Ensure full compliance with applicable electrical safety standards and statutory requirements.
- 16. Monitor real-time equipment parameters through the BMS, temperature monitoring systems, and energy meters.
- 17. Conduct daily walkthroughs to identify abnormalities, unusual sounds, vibrations, or visual defects in equipment.
- 18. Track and maintain equipment runtime hours, energy consumption data, and performance trends.
- 19. Ensure all monitoring sensors and alarm systems are calibrated and fully functional at all times.
- 20. Daily Reports — Prepare and submit daily equipment status reports covering temperature logs, DG runtime, UPS status, and all observed anomalies.
- 21. Weekly Reports — Compile weekly maintenance summary reports covering PPM compliance, breakdown analysis, spare parts consumption, and pending work orders.
- 22. Monthly Reports — Develop monthly performance reports inclusive of equipment uptime percentage, Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), energy consumption trends, and cost analysis.
- 23. Conduct structured Root Cause Analysis (RCA) for all equipment breakdowns, temperature excursions, and safety incidents using methodologies such as Five-Why Analysis and Fishbone Diagrams.
- 24. Develop and implement Corrective and Preventive Actions (CAPA) with clearly defined timelines, responsible owners, and effectiveness verification criteria.
- 25. Maintain a CAPA tracker with closure status, evidence of implementation, and effectiveness validation records.
- 26. Present RCA and CAPA findings during Weekly Business Reviews (WBR) and Monthly Business Reviews (MBR).
- Qualifications & Skills
- Education — Diploma or bachelor’s degree in mechanical engineering, Electrical Engineering, or Refrigeration & Air Conditioning.
- Experience — Minimum three to five years of hands-on experience in refrigeration systems and base building equipment maintenance.
- Technical Knowledge — Proficiency in refrigeration cycles, electrical systems, DG operations, UPS systems, and BMS platforms.
- Certifications — Preferred certifications in Refrigeration & Air Conditioning, Electrical Safety, or equivalent recognised standards.
- Analytical Skills — Ability to perform structured RCA, develop CAPA plans, and apply data-driven decision-making.
- Reporting Skills — Proficiency in preparing technical reports, dashboards, and MIS outputs using MS Excel and relevant tools.
- Communication — Clear verbal and written communication skills for effective cross-functional coordination.
- Working Conditions
- Shift-based operations with rotational shifts as applicable to site requirements.
- Sustained exposure to cold room environments, including frozen rooms operating at sub-zero temperatures.
- Regular work in proximity to live electrical systems — adherence to all safety protocols is mandatory.
- On-call availability required for emergency breakdowns and critical temperature excursion response.
- Key job responsibilities
- Key Responsibilities
- 1. Execute planned preventive maintenance (PPM) schedules for all refrigeration systems, including tropical rooms, chilled rooms, and frozen rooms.
- 2. Monitor and maintain optimal temperature parameters across all cold chain zones in strict accordance with defined Standard Operating Procedures (SOPs).
- 3. Conduct routine inspections of compressors, condensers, evaporators, expansion valves, and refrigerant piping systems.
- 4. Ensure refrigerant levels are maintained within specified limits and perform periodic leak detection tests.
- 5. Monitor and maintain defrost cycles, drain lines, and insulation integrity of all cold rooms.
- 6. Coordinate with Original Equipment Manufacturers (OEMs) and third-party service providers for specialized repairs and annual maintenance contracts.
- 7. Diagnose and resolve refrigeration system faults, including compressor failures, refrigerant leaks, thermostat malfunctions, and evaporator icing.
- 8. Respond to temperature excursion alarms and execute corrective actions within defined response timelines.
- 9. Troubleshoot electrical and control system faults in refrigeration panels, PLCs, and Building Management System (BMS) interfaces.
- 10. Perform root cause identification for recurring equipment failures and implements verified permanent fixes.
- 11. Maintain and monitor Diesel Generator (DG) sets, including fuel systems, coolant levels, battery health, and periodic load bank testing.
- 12. Execute preventive and predictive maintenance on Uninterruptible Power Supply (UPS) systems, including battery health checks, load testing, and firmware updates.
- 13. Monitor and maintain electrical panels — including Main Distribution Boards (MDB), Sub-Distribution Boards (SDB), Automatic Transfer Switches (ATS), and change-over panels.
- 14. Conduct periodic insulation resistance (IR) testing, earth resistance testing, and thermography surveys of all electrical systems.
- 15. Ensure full compliance with applicable electrical safety standards and statutory requirements.
- 16. Monitor real-time equipment parameters through the BMS, temperature monitoring systems, and energy meters.
- 17. Conduct daily walkthroughs to identify abnormalities, unusual sounds, vibrations, or visual defects in equipment.
- 18. Track and maintain equipment runtime hours, energy consumption data, and performance trends.
- 19. Ensure all monitoring sensors and alarm systems are calibrated and fully functional at all times.
- 20. Daily Reports — Prepare and submit daily equipment status reports covering temperature logs, DG runtime, UPS status, and all observed anomalies.
- 21. Weekly Reports — Compile weekly maintenance summary reports covering PPM compliance, breakdown analysis, spare parts consumption, and pending work orders.
- 22. Monthly Reports — Develop monthly performance reports inclusive of equipment uptime percentage, Mean Time Between Failures (MTBF), Mean Time To Repair (MTTR), energy consumption trends, and cost analysis.
- 23. Conduct structured Root Cause Analysis (RCA) for all equipment breakdowns, temperature excursions, and safety incidents using meth
Similar jobs
- Maintenance EngineerSuyash Global · Navi Mumbai, Maharashtra, IndiaFirst seen today
- Maintenance EngineerSuyash Global · Navi Mumbai, Maharashtra, IndiaFirst seen today
- Maintenance EngineerSVKM enterprize · NMIMS Campus Office, Shirpur, IndiaFirst seen yesterday
- Scenario Creation - Maintenance EngineerInfosys · Bangalore, IndiaFirst seen yesterday
- Maintenance EngineerValeo · PuneFirst seen yesterday
Want this one?
Upload your resume and hirly rewrites it for this job and writes the cover letter — in about thirty seconds, before you sign up.
Tailor my resume for this job