hirly

Data Airflow

Facility Service Technician — Electrical

Barker, New York

hirly Pro

Get in front of the people hiring at Data Airflow

  • Reach the hiring manager at Data Airflow on LinkedIn, from your own account
  • hirly applies to this job for you, with unlimited applications
  • A resume and cover letter written for this job, unlimited
  • The hiring manager and recruiter at Data Airflow, with contact details
Get Pro for this job →

$49 a month · ₹1,999 for 30 days in India · cancel any time

See how you match this job — and similar ones. Free.

Upload your resume and hirly scores it against this role at Data Airflow first, then against similar open jobs, and shows where you fit and why.

PDF or DOCX, up to 12MB. No sign-up to see your matches.

Get past the screening software and onto a recruiter's desk

hirly rewrites your resume for this job — matching the keywords and skills in the posting, moving your most relevant experience to the top, and writing a cover letter to fit. About 30 seconds.

  • Keywords matched to this posting
  • Fit score before you apply
  • Cover letter included

Matched against 2.8M live jobs from 220,000+ employers in 200+ countries.

Tailor my resume for this job →

Apply from your AI assistant

Connect hirly to Claude or ChatGPT and ask it to apply to this job. hirly tailors your resume, fills the employer’s form and asks before sending.

Some employer sites stop an application at a CAPTCHA or sign-in and hand it back with a link. Applying needs a paid plan. Works with any assistant that supports MCP.

hirly's read of this role

Seniority
Mid level
Country
US
Work mode
On-site / unstated
First seen by hirly
1 Sept 2026

Derived automatically from the posting. Upload your resume above to see how the role scores against it.

the posting

About Your Role

The Facility Service Technician — Electrical is a Data Airflow (DAF) employee deployed as embedded supplemental support staff within a client data center facility. Day-to-day directives and operational priorities are driven by the client’s facility management team, including their Director of Operations, Facility Manager(s), and Engineering Manager(s). This role is critical to sustaining the electrical reliability and resilience of a large-scale, mission-critical data center environment. The technician operates, maintains, inspects, and troubleshoots a full range of electrical power distribution, protection, and conditioning systems to ensure continuous uptime.

What You’ll Do (Job Responsibilities)

● Perform routine and corrective maintenance on electrical systems throughout the facility, including 120V control power wiring, 480V distribution wiring, Uninterruptible Power Supplies (UPS), Automatic Transfer Switches (ATS), and Static Transfer Switches (STS).

● Inspect, maintain, and troubleshoot motors and Variable Frequency Drives (VFDs) to support mechanical and cooling system reliability.

● Monitor and document electrical system performance including power quality, load readings, and alarm states across distribution infrastructure.

● Conduct and document regular building rounds, recording readings from electrical distribution and power conditioning equipment.

● Execute preventive maintenance (PM) work orders, method of procedure (MOP) tasks, and corrective maintenance activities within client SLA requirements.

● Support safe, coordinated electrical switching and isolation operations under established MOP frameworks and Lockout/Tagout (LOTO) protocols.

● Assist in root cause analysis (RCA) and incident documentation following electrical anomalies, equipment failures, or power events.

● Coordinate with client engineering staff, third-party vendors, and service contractors for scheduled maintenance and emergent repairs.

● Maintain accurate records within the facility’s Computerized Maintenance Management System (CMMS).

● Support commissioning and testing activities for electrical infrastructure as directed.

● Uphold all DAF and site-specific electrical safety standards, including NFPA 70E arc flash and shock hazard protocols and permit-to-work requirements.

● Other duties as assigned.

What You’ll Need to Get the Job Done:

● 3+ years of hands-on electrical maintenance experience in a data center, mission-critical facility, industrial, or equivalent environment.

● Demonstrated proficiency with 120V control power wiring and 480V electrical systems, including UPS, ATS, and STS.

● Solid working knowledge of three-phase electrical systems, power distribution, and power conditioning equipment.

● Familiarity with motors and VFDs, including troubleshooting and basic commissioning support.

● Ability to read and interpret single-line diagrams, panel schedules, equipment schematics, and technical manuals.

● Strong troubleshooting capability with the ability to diagnose and resolve complex electrical failures under pressure.

● NFPA 70E qualification or site-equivalent electrical safety training (required).

● Experience with CMMS platforms to log work orders, track PM completion, and document findings.

● Preferred: Experience with medium-voltage (13.8 kV) electrical systems and associated protective equipment.

● Preferred: Familiarity with relay protection schemes and relay settings configuration.

● Preferred: Journeyman Electrician license or equivalent trade certification.

● Preferred: OSHA 10 or OSHA 30 certification.

● Physical ability to perform the demands of the role: prolonged standing and walking, working in confined spaces and elevated work areas, and lifting up to 50 lbs.

● Valid driver’s license with reliable transportation.

Data Airflow is a proud Equal Opportunity Employer

Original posting on Data Airflow's site ↗

Listed on hirly, a job board. hirly is not the employer: Data Airflow is hiring for this role.

Browse similar roles

Want this one?

Upload your resume and hirly rewrites it for this job and writes the cover letter — in about thirty seconds, before you sign up.

Tailor my resume for this job